HOME  |  CONTACT  |  DEUTSCH

RFID Reader Serial

Short features:

LF80 RFID Reader Serial
  • Stationary Transponder reader
  • TIRIS™ tag compatible
  • Automatic antenna calibration
  • Synchronisation when using several devices
  • Parallel interface (serial)
  • LEDs for status display
  • Available with SECS-1 or ASC-I1 protocol
  • low MTTR, due to plug & play components
  • high reliable device, MBTF >75 years

Product description

Brooks Automation offers the RFID reader LF80 Serial, a read/write system of extraordinary quality and functionality. The device uses the frequency LF and communicates with TIRIS™ transponders by Texas Instruments.

At the touch of a button a test mode can be started, in which the system adapts to its surroundings and adjusts the perfect read/write range for the antenna. In addition, a test button allows the inspection of all functions without interrupting the operation of the overall system.

These functions make it easy to integrate the device into the process periphery and allow for handling the system without the need for a comprehensive RFID understanding.

The RFID reader LF80 Serial has several LEDs to display the status. They provide information on the current operational mode, voltage, antenna mode and read/write status as well as displaying I/O signals. The reader supposes of a second parallel interface (RS232) for easy maintenance.

The combination with a Brooks gateway enables the connection with other communication systems. If required, this device is also available with other protocols.

Part number:

TLG-S2-1O00-S0-00EB

Protocol SECS

TLG-I2-1O00-S0-00EB

Protocol ASCII

Specifications

Protocol SECS-1 or ASC-I1  
Dimensions 172 mm x 80 mm x 43 mm 6.8 in. x 3.2 in. x 1.7 in.
Weight 440 g 15.5 oz
Operating temperature 0°C to 50°C 32°F to 122°F
Storage temperature -25°C to 70°C -13°F to 158°F
Permissible humidity 25% to 80% at 50°C 122°F  
Protection mode IP40  
Housing ABS (UL94-V0)  
Fuse Typ TR5400 mA  
Serial Interface RS232300 Bd - 115.2 kBd  
Voltage 18 - 30 V DC  
Current 30 mA  
Reading / Writing impulse Rod antenna 160 mA  
Reading / Writing impulse Micro antenna 140 mA  
SEMI Standards E4/ E5/ E99.1/ E144  